{"title":"12V IP67 recessed spotlights","description":"\u003cp\u003e\u003cstrong\u003e12V IP67 recessed spotlights are powered by a transformer that steps down the mains voltage, and their IP67 rating protects them from dust as well as temporary immersion.\u003c\/strong\u003e This is the fitting for terrace floors, pathways and very wet rooms, where a 220V spot or an IP44 would let water in. You choose it first by its real use and its protection rating, then by its orientation and finish.\u003c\/p\u003e\n\n\u003ch2 id=\"quest-ce\"\u003eWhat is a 12V IP67 recessed spotlight and where should you install it?\u003c\/h2\u003e\n\u003cp\u003eA grazing halo on a terrace, a bathroom floor lit without harsh glare: the effect comes from positioning as much as from the fitting. On the technical side, very low voltage 12V requires a transformer, and the IP67 rating guarantees dust-tightness and resistance to temporary immersion.\u003c\/p\u003e\n\n\u003ch3\u003e12V IP67 recessed spotlight or 220V spotlight: what does low voltage change?\u003c\/h3\u003e\n\u003cp\u003eLow voltage simplifies installation near a water point, since a remote transformer keeps the 220V away from the wet zone. On the other hand, voltage drop must be watched on long runs and the transformer must remain accessible. 220V connects directly and handles distances better, which makes it suited to areas away from water.\u003c\/p\u003e\n\n\u003ch3\u003eIP67 recessed spotlights: floor, terrace or wet room?\u003c\/h3\u003e\n\u003cp\u003eRecessed into the floor of a terrace, a pathway or a drive, IP67 is the consistent level: water can pool on the glass without damage. In a bathroom or utility room ceiling, IP65 is often enough, since splashes stay vertical. To compare the two approaches, browse the \u003ca href=\"https:\/\/designix.fr\/collections\/spots-d-exterieur-encastrables\"\u003eoutdoor recessed spotlights\u003c\/a\u003e and their floor-mounted variants.\u003c\/p\u003e\n\n\u003ch2 id=\"quel-ip\"\u003eWhich IP rating for an outdoor spotlight?\u003c\/h2\u003e\n\u003cp\u003eThe IP rating must cover both dust and water, with a margin over the real exposure. Under a canopy or on a facade sheltered by a roof overhang, IP65 protects against water jets. As soon as the fitting sits on the ground, on a terrace or in a pathway where water pools, IP67 becomes the safe choice. IP44 remains a wet interior use, not an exposed outdoor one. Also look at the \u003ca href=\"\/collections\/spots-d-exterieur-led-encastrables\"\u003eLED versions for outdoor use\u003c\/a\u003e, which lighten the load drawn from the transformer.\u003c\/p\u003e\n\n\u003ch2 id=\"difference-ip\"\u003eWhat is the difference between IP44, IP65 and IP67?\u003c\/h2\u003e\n\u003cp\u003eThe first digit indicates protection against solids, the second against water. IP44 protects against splashes, IP65 against water jets, IP67 against temporary immersion. An IP67 is therefore neither brighter nor more powerful: it is simply more watertight, which matters on the ground and on a terrace.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eIP rating\u003c\/th\u003e\n\u003cth\u003eSolid protection\u003c\/th\u003e\n\u003cth\u003eWater protection\u003c\/th\u003e\n\u003cth\u003eSuitable use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP44\u003c\/td\u003e\n\u003ctd\u003eForeign bodies over 1 mm\u003c\/td\u003e\n\u003ctd\u003eWater splashes\u003c\/td\u003e\n\u003ctd\u003eWet room, under a sheltered canopy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003ctd\u003eLimited dust\u003c\/td\u003e\n\u003ctd\u003eWater jets\u003c\/td\u003e\n\u003ctd\u003eSheltered outdoors, facade under an overhang\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP64\u003c\/td\u003e\n\u003ctd\u003eLimited dust\u003c\/td\u003e\n\u003ctd\u003eWater splashes\u003c\/td\u003e\n\u003ctd\u003eBathroom, very wet interior\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003ctd\u003eDust-tight\u003c\/td\u003e\n\u003ctd\u003eLance water jets\u003c\/td\u003e\n\u003ctd\u003eFacade spotlight, covered terrace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003ctd\u003eDust-tight\u003c\/td\u003e\n\u003ctd\u003ePowerful water jets\u003c\/td\u003e\n\u003ctd\u003eOutdoors exposed to rain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003ctd\u003eDust-tight\u003c\/td\u003e\n\u003ctd\u003eTemporary immersion\u003c\/td\u003e\n\u003ctd\u003eRecessed in the ground, terrace, pathway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat is the difference between IP65 and IP67?\u003c\/h3\u003e\n\u003cp\u003eBoth are dust-tight. IP65 resists water jets, which covers driving rain and jet cleaning. IP67 adds resistance to temporary immersion, useful when the fitting sits flush with a floor where water accumulates. At equal voltage, only the watertightness level changes.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is the difference between IP44 and IP65?\u003c\/h3\u003e\n\u003cp\u003eIP44 tolerates splashes and lets fine bodies through; IP65 shuts out dust and withstands jets. The second digit is the real break: an IP44 fitted on a wooden facade takes in water at the first storm. For a terrace wall, compare the \u003ca href=\"\/collections\/spots-encastrables-orientables\"\u003eadjustable recessed spotlights\u003c\/a\u003e, which direct the beam toward the wall rather than the sky.\u003c\/p\u003e\n\n\u003ch2 id=\"salle-de-bain\"\u003eShould you use 12V or 220V spotlights for the bathroom?\u003c\/h2\u003e\n\u003cp\u003eThe choice depends on the distance to the bathtub or shower and on exposure to splashes. Very low voltage 12V, with a transformer placed outside the wet zone, simplifies installation near water. 220V remains possible further away, around the mirror or above the washbasin.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCriterion\u003c\/th\u003e\n\u003cth\u003e12V spotlight\u003c\/th\u003e\n\u003cth\u003e220V spotlight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e12V transformer or driver required\u003c\/td\u003e\n\u003ctd\u003eDirectly on the mains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear a water point\u003c\/td\u003e\n\u003ctd\u003eVery low voltage, frequent choice\u003c\/td\u003e\n\u003ctd\u003eReserved for areas away from water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length\u003c\/td\u003e\n\u003ctd\u003eVoltage drop to watch\u003c\/td\u003e\n\u003ctd\u003eLess sensitive to distance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecessed in the ground\u003c\/td\u003e\n\u003ctd\u003eCommon solution, remote transformer\u003c\/td\u003e\n\u003ctd\u003eLess frequent outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance\u003c\/td\u003e\n\u003ctd\u003eAccessible transformer to plan for\u003c\/td\u003e\n\u003ctd\u003eReplacement of the spotlight alone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e12V spotlight in a bathroom: where to place the transformer?\u003c\/h3\u003e\n\u003cp\u003eOutside the splash zone, in a dry and accessible place: service duct, box above a removable ceiling, or storage cabinet. An inaccessible transformer means taking everything down the day it fails. Note its power and location on the installation plan.\u003c\/p\u003e\n\n\u003ch3\u003eIs 220V still possible away from the shower?\u003c\/h3\u003e\n\u003cp\u003eYes, as soon as the fitting is no longer directly exposed to splashes. Above a mirror or a vanity top away from the bathtub, a classic recessed spotlight is suitable. For adjustable light around the mirror, \u003ca href=\"\/collections\/spots-encastrables-a-variateur\"\u003edimmable spotlights\u003c\/a\u003e prevent glare when you wake up.\u003c\/p\u003e\n\n\u003ch2 id=\"installer-plafond\"\u003eHow to install recessed spotlights in the ceiling?\u003c\/h2\u003e\n\u003cp\u003eYou mark the position, check for joists and conduit, then drill with a hole saw at the diameter indicated for the fitting. The cable passes through the hole, the transformer stays accessible, the spotlight is fixed with springs. The power is switched off before any handling.\u003c\/p\u003e\n\n\u003ch3\u003eHow to prepare the drilling before fitting a spotlight?\u003c\/h3\u003e\n\u003cp\u003eA stud detector passed over the area avoids cutting through a joist or a pipe. You draw the grid in pencil and check the alignment by eye from the room entrance, before drilling. The hole saw diameter matches that of the trim, not that of the housing.\u003c\/p\u003e\n\n\u003ch3\u003eShould the transformer be left accessible?\u003c\/h3\u003e\n\u003cp\u003eYes, it is the part that ages fastest on a 12V line. An inspection hatch or a removable ceiling solves the problem. Without access, replacing a driver means working on the whole circuit. For a terrace, cross-check this point with the \u003ca href=\"\/collections\/spots-d-exterieur-encastrables-orientables\"\u003eadjustable terrace models\u003c\/a\u003e, often installed on the ground with a remote driver.\u003c\/p\u003e\n\n\u003ch2 id=\"brancher\"\u003eHow to wire spotlights in series or in parallel?\u003c\/h2\u003e\n\u003cp\u003eIn parallel, each spotlight receives the same voltage and keeps lighting if another fails: this is the preferred wiring. In series, the voltage is shared and one failure cuts the whole line. On 12V, you mainly check the transformer's total power and the cable length.\u003c\/p\u003e\n\n\u003ch3\u003eHow to wire spotlights in series?\u003c\/h3\u003e\n\u003cp\u003eSeries wiring connects the fittings end to end: the supply voltage is divided between them. It is reserved for special cases, because each spotlight receives less voltage and the lighting gradually weakens. A single burnt-out lamp switches off the entire circuit.\u003c\/p\u003e\n\n\u003ch3\u003eWhy wire spotlights in parallel?\u003c\/h3\u003e\n\u003cp\u003eBecause each fitting keeps its independence and full voltage, and troubleshooting is limited to the spotlight concerned. The transformer is sized with a margin over the combined power, and reasonable cable lengths are kept. \u003ca href=\"\/collections\/spots-encastrables-design\"\u003eDesigner spotlights\u003c\/a\u003e are wired the same way; the finish changes nothing in the diagram.\u003c\/p\u003e\n\n\u003ch2 id=\"disposer\"\u003eHow to lay out spotlights in the ceiling?\u003c\/h2\u003e\n\u003cp\u003eYou place the points in a regular grid, keeping a distance from the wall to avoid cast shadows, and aligning the rows with the lines of the room. Better a few well-placed points aimed at the areas of use than tightly spaced spotlights lighting empty space.\u003c\/p\u003e\n\n\u003ch3\u003eHow to lay out spotlights in a hallway?\u003c\/h3\u003e\n\u003cp\u003eIn a single line along the axis, evenly spaced, rather than staggered: the eye follows the perspective and regularity matters more than number. \u003ca href=\"\/collections\/spots-pour-couloir\"\u003eHallway spotlights\u003c\/a\u003e gain discretion by staying fixed or slightly adjustable. Avoid placing a point right above the entrance door, the shadow of the frame eats the light.\u003c\/p\u003e\n\n\u003ch3\u003eShould you light the walls or the centre of the room?\u003c\/h3\u003e\n\u003cp\u003eThe centre lights the floor, the wall lights the room. A grazing beam on a wall visually enlarges the space and softens the light; this is the useful move in a living room. For this effect, adjustable \u003ca href=\"\/collections\/spots-encastrables-pour-salon\"\u003erecessed living room lighting\u003c\/a\u003e is better than a grid in the centre.\u003c\/p\u003e\n\n\u003ch2 id=\"cuisine\"\u003eHow many spotlights in a kitchen?\u003c\/h2\u003e\n\u003cp\u003eThe number is calculated from the surface area, the ceiling height and the power of the fittings, not from a single figure. You light the worktop and the sink first, then the circulation areas, avoiding placing a point right behind the head of whoever is cooking.\u003c\/p\u003e\n\n\u003ch3\u003eWhere to place spotlights in a kitchen?\u003c\/h3\u003e\n\u003cp\u003eIn a line above the worktop, offset from the wall so the beam falls on the board and not on the user's back. The sink and the hob get a dedicated point. Adjustable \u003ca href=\"\/collections\/spots-encastrables-pour-cuisine\"\u003ekitchen spotlights\u003c\/a\u003e allow this setting to be adjusted after installation.\u003c\/p\u003e\n\n\u003ch3\u003eRecessed spotlights or under-cabinet strip?\u003c\/h3\u003e\n\u003cp\u003eAn under-cabinet strip highlights the worktop without glare and usefully replaces a badly placed spotlight; the ceiling recessed spotlight provides the general light. The two complement each other. \u003ca href=\"\/collections\/spots-led-pour-cuisine\"\u003eLED kitchen spotlights\u003c\/a\u003e lighten the load on the circuit and limit heat above the wall units.\u003c\/p\u003e\n\n\u003ch2 id=\"puissance\"\u003eWhich power to choose for a recessed LED spotlight?\u003c\/h2\u003e\n\u003cp\u003ePower is chosen according to use: a low value is enough for ambient or floor lighting, a higher value becomes useful at height or for lighting a worktop. Colour temperature and beam angle matter as much as the watts.\u003c\/p\u003e\n\n\u003ch3\u003eWhich power for ambience and for a worktop?\u003c\/h3\u003e\n\u003cp\u003eFor ambience, you want soft, distributed light with a wide beam: the power stays low. On a worktop or a desk, the beam narrows and the power rises so the task is sharp. A high ceiling requires more power than a low ceiling for the same effect.\u003c\/p\u003e\n\n\u003ch3\u003eDoes colour temperature change the result?\u003c\/h3\u003e\n\u003cp\u003eYes. Around 2,700 to 3,000 K, the light leans toward warm white and suits living rooms; toward 4,000 K, it becomes more neutral and readable, useful in a kitchen and a hallway. Above 5,000 K, the result cools and tires the eye in a bedroom. To harmonise several rooms, \u003ca href=\"\/collections\/spots-encastrables-coloris-blanc\"\u003ediscreet white finishes\u003c\/a\u003e and \u003ca href=\"\/collections\/spots-encastrables-coloris-noir\"\u003eblack spotlights\u003c\/a\u003e blend without visual break.\u003c\/p\u003e\n\n\u003ch2 id=\"choisir-finition\"\u003eHow to match the spotlight with the rest of the room?\u003c\/h2\u003e\n\u003cp\u003eThe trim finish decides the discretion of the fitting: white on a painted ceiling, black on dark joinery, gold or metal to embrace contrast. A floor recessed spotlight in \u003ca href=\"\/collections\/spots-en-metal\"\u003emetal spotlights\u003c\/a\u003e withstands foot traffic better than a plastic trim.\u003c\/p\u003e\n\n\u003ch3\u003eWhich finish for a ceiling and for a floor?\u003c\/h3\u003e\n\u003cp\u003eOn the ceiling, the trim blends into the paint: matte white for a white ceiling, and \u003ca href=\"\/collections\/spots-encastrables-coloris-dore\"\u003egold models\u003c\/a\u003e for an interior that plays with brass. On the floor, the material matters more than the shade, with a treated metal and a high IP rating. \u003ca href=\"\/collections\/spots-led-encastrables-coloris-noir\"\u003eBlack recessed LED spotlights\u003c\/a\u003e discreetly mark a dark terrace.\u003c\/p\u003e\n\n\u003ch3\u003eCan you mix several orientations in the same room?\u003c\/h3\u003e\n\u003cp\u003eYes, provided you keep the same finish family and the same colour temperature. A fixed one for general light, an adjustable one for the wall: the mix stays consistent if the shade does not vary. To push the adjustment further, \u003ca href=\"\/collections\/spots-led-encastrables-orientables\"\u003eadjustable LED variants\u003c\/a\u003e and \u003ca href=\"\/collections\/spots-led-encastrables-a-variateur\"\u003edimmable LED spotlights\u003c\/a\u003e combine on the same line.\u003c\/p\u003e\n\n\u003ch2 id=\"reassurance\"\u003eOrdering and preparing your installation\u003c\/h2\u003e\n\u003cp\u003eBefore confirming, note three things: the IP rating required by the location, the drilling diameter and the power available on the transformer. These three figures prevent most returns. Payment is secure, delivery is tracked and returns are handled by the Designix customer service.\u003c\/p\u003e\n\u003cp\u003eTo place this fitting among the other families in the home, compare with \u003ca href=\"\/collections\/luminaire\"\u003eall the home lighting\u003c\/a\u003e, then refine by room: \u003ca href=\"\/collections\/spots-led-encastrables-pour-cuisine\"\u003erecessed LED kitchen spotlights\u003c\/a\u003e for a worktop, or the \u003ca href=\"\/collections\/luminaire\"\u003efull lighting catalogue\u003c\/a\u003e for a larger renovation project. One last useful marker: a wet room requires a higher rating than a dry room, whatever the style chosen.\u003c\/p\u003e\n\n\u003ch2 id=\"faq\"\u003eFrequently asked questions\u003c\/h2\u003e\n\n\u003cdetails\u003e\u003csummary\u003eWhat does IP64 watertightness mean?\u003c\/summary\u003e\u003cp\u003eIP64 combines protection against limited dust and protection against water splashes. It is a wet interior rating, suitable for a bathroom or a utility room, but not for a floor recessed spotlight exposed to rain, where IP67 is more consistent.\u003c\/p\u003e\u003c\/details\u003e\n\n\u003cdetails\u003e\u003csummary\u003eWhat is the difference between IP55, IP65 and IP66?\u003c\/summary\u003e\u003cp\u003eAll three protect against dust to different degrees and against water jets. IP55 tolerates limited dust and moderate jets, IP65 is dust-tight and resists lance jets, IP66 withstands more powerful jets. The choice depends on the real exposure of the fitting.\u003c\/p\u003e\u003c\/details\u003e\n\n\u003cdetails\u003e\u003csummary\u003eIs the IP44 standard mandatory for bathroom lighting?\u003c\/summary\u003e\u003cp\u003eIP44 is a level of protection, not an obligation in itself: the required rating depends on the bathroom zone and proximity to water. Near a bathtub or shower, you increase protection and favour very low voltage 12V. Beyond the wet zone, a lower rating may be enough.\u003c\/p\u003e\u003c\/details\u003e\n\n\u003cdetails\u003e\u003csummary\u003e12V IP65 recessed spotlight or IP67 recessed spotlight: which to choose?\u003c\/summary\u003e\u003cp\u003eA 12V IP65 recessed spotlight is suitable on a sheltered facade, under a canopy or in a wet room ceiling. IP67 is essential as soon as the fitting is placed on the ground, on a terrace or in a pathway where water can pool. At equal voltage, only the watertightness level changes.\u003c\/p\u003e\u003c\/details\u003e\n\n\u003cdetails\u003e\u003csummary\u003eCan a 12V IP67 spotlight be installed without a transformer?\u003c\/summary\u003e\u003cp\u003eNo: a 12V spotlight needs a transformer or driver that steps down the mains voltage. This transformer is placed outside the wet zone, in a place accessible for maintenance, and its power must cover all the spotlights connected on the same line.\u003c\/p\u003e\u003c\/details\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"CollectionPage\",\"name\":\"12V IP67 recessed spotlights: choosing, wiring and installing\",\"description\":\"Choosing a 12V IP67 recessed spotlight by use and protection rating: differences between IP44, IP65 and IP67, wiring and installation steps.\",\"url\":\"https:\/\/designix.fr\/collections\/spots-encastrables-12v-ip67\",\"isPartOf\":{\"@type\":\"WebSite\",\"name\":\"Designix\",\"url\":\"https:\/\/designix.fr\"},\"speakable\":{\"@type\":\"SpeakableSpecification\",\"cssSelector\":[\"h1\",\"h2\"]}},{\"@type\":\"BreadcrumbList\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/designix.fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Lighting\",\"item\":\"https:\/\/designix.fr\/collections\/luminaire\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Spotlights\",\"item\":\"https:\/\/designix.fr\/collections\/spots\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"12V IP67 recessed spotlights: choosing, wiring and installing\",\"item\":\"https:\/\/designix.fr\/collections\/spots-encastrables-12v-ip67\"}]},{\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What does IP64 watertightness mean?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"IP64 combines protection against limited dust and protection against water splashes. It is a wet interior rating, suitable for a bathroom or a utility room, but not for a floor recessed spotlight exposed to rain, where IP67 is more consistent.\"}},{\"@type\":\"Question\",\"name\":\"What is the difference between IP55, IP65 and IP66?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"All three protect against dust to different degrees and against water jets. IP55 tolerates limited dust and moderate jets, IP65 is dust-tight and resists lance jets, IP66 withstands more powerful jets. The choice depends on the real exposure of the fitting.\"}},{\"@type\":\"Question\",\"name\":\"What is the difference between IP44 and IP65?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"IP44 protects against foreign bodies over 1 mm and water splashes: it is a wet room rating. IP65 adds dust-tightness and resistance to water jets, which makes it suitable for sheltered outdoor use. The second digit makes all the difference near a terrace.\"}},{\"@type\":\"Question\",\"name\":\"Is the IP44 standard mandatory for bathroom lighting?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"IP44 is a level of protection, not an obligation in itself: the required rating depends on the bathroom zone and proximity to water. Near a bathtub or shower, you increase protection and favour very low voltage 12V. Beyond the wet zone, a lower rating may be enough.\"}},{\"@type\":\"Question\",\"name\":\"12V IP65 recessed spotlight or IP67 recessed spotlight: which to choose?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A 12V IP65 recessed spotlight is suitable on a sheltered facade, under a canopy or in a wet room ceiling. IP67 is essential as soon as the fitting is placed on the ground, on a terrace or in a pathway where water can pool. At equal voltage, only the watertightness level changes.\"}},{\"@type\":\"Question\",\"name\":\"Can a 12V IP67 spotlight be installed without a transformer?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No: a 12V spotlight needs a transformer or driver that steps down the mains voltage. This transformer is placed outside the wet zone, in a place accessible for maintenance, and its power must cover all the spotlights connected on the same line.\"}},{\"@type\":\"Question\",\"name\":\"How many spotlights in a kitchen?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"There is no single number: it all depends on the surface area, the ceiling height and the power of the fittings. You count by zones to be lit, worktop, sink, circulation areas, then distribute the points to avoid cast shadows in front of the units.\"}}]}]}\u003c\/script\u003e","products":[{"product_id":"spot-encastrable-led-ld2103-12v-ip68-en-verre-acier-inoxydable-et-transparent-o-1-8-cm","title":"Spot encastrable LED LD2103 12V IP68 en verre, acier inoxydable et transparent, Ø 1,8 cm","description":"\u003cp\u003eCe spot encastrable LED est réalisé en acier inoxydable et verre, coloris acier inoxydable et transparent. Il mesure 1,8 cm de diamètre et 0,1 cm de hauteur. Ses LED intégrées éclairent. Points pratiques : indice de protection IP68.\u003c\/p\u003e\u003ch3\u003eCaractéristiques techniques\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCouleur\u003c\/strong\u003e : acier inoxydable \/ transparent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatériau(x)\u003c\/strong\u003e : Acier inoxydable \/ Verre\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHauteur (en cm)\u003c\/strong\u003e : 0,1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiamètre (en cm)\u003c\/strong\u003e : 1,8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiamètre d'encastrement (en cm)\u003c\/strong\u003e : 1,3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfondeur d'encastrement (en cm)\u003c\/strong\u003e : 1,4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoids net (kg)\u003c\/strong\u003e : 0,049\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmpoule\u003c\/strong\u003e : 1 LED de 0,2 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmpoule incluse\u003c\/strong\u003e : Oui\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWattage\u003c\/strong\u003e : 0,2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmpoules LED intégrées au luminaire\u003c\/strong\u003e : Oui\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRendu des couleurs (en Ra)\u003c\/strong\u003e : 80\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAngle de rayonnement\u003c\/strong\u003e : 100\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntensité variable\u003c\/strong\u003e : Non\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection IP\u003c\/strong\u003e : IP68\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClasse de protection\u003c\/strong\u003e : III\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlimentation (en Volt)\u003c\/strong\u003e : 12\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eExpédié sous 12 à 14 jours ouvrés\u003c\/strong\u003e\u003c\/p\u003e","brand":"EVN","offers":[{"title":"Default Title","offer_id":55296957808978,"sku":"LW-4026107","price":64.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0677\/8598\/2228\/files\/4026107_60764de3-20e8-413f-a03e-5081640eecfc.jpg?v=1793624301"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0677\/8598\/2228\/collections\/designix-entete-spots-encastrables-12v-ip67-v1.jpg?v=1792971565","url":"https:\/\/designix-lighting.com\/collections\/12v-ip67-recessed-spotlights.oembed","provider":"Designix","version":"1.0","type":"link"}